Geberit urinal flush control with electronic flush actuation, mains operation, actuator plate made of plastic
My list (0)
Technical data
Protection degree IP45 |
Nominal voltage 110–240 V AC |
Operating voltage 4.5 V DC |
Mains frequency 50 Hz |
Flow pressure 1–8 bar |
Test pressure, water max. 16 bar |
Storage temperature -20 – +70 °C |
Operating temperature 1–50 °C |
Minimum flow pressure for calculated flow rate 1 bar |
Calculated flow rate 0.23 l/s |
Interval flush, adjustment range 1–168 h |
Detection time, adjustment range 3–10 s |
Detection time, factory setting 7 s |
Flush time, adjustment range 1–15 s |
Flush time, factory setting 7 s |
Application purposes
Characteristics
Scope of delivery
Cover plate with IR window
Mounting frame
Infrared control
Solenoid valve
Power supply unit
Fastening material
Documents
Your input does not return any results
Spare parts
Urinal flush controls with electronic flush actuation, mains operation, Basic
Urinal flush controls with electronic flush actuation, mains operation, Basic
2013 -
# | Art. no. | Description | Remarks |
---|---|---|---|
1 | 240.560.11.1 | cover plate for UR-ctrl IR | Die-cast zinc |
1 | 240.560.46.1 | Die-cast zinc | |
1.2 | 240.525.00.1 | IR windows UR-ctrl | |
19 Articles